What are the probable causes for failure of the pump to deliver water?
 

The various possible reasons for failure and the remedial measures thereof are elucidated as follows:

If the speed is too low, check the voltage supply & frequency. Change cable with correct size if required.

If air enters into the suction pipe, make air tight joints or if required, replace the pipe.
If there is no water in the pump set, fill water in the pump chambers / casing.
If the suction pipe has too many bends, educe the number of bends if possible.
If the mechanical seal is leaking, refit the mechanical seal or replace it.
If the suction lift is too high, move the pump installation nearer to water level.
If the direction of rotation is wrong, correct it.
   

What makes the pump discharge less, and what needs to be done to
correct it?

 

The probable reasons and the corresponding corrective actions are as listed below:

If the suction pipe inlet is inadequately submerged in water, move installation nearer to the water level.

If the suction lift is too high, reduce the height.
If the suction pipe and strainer is clogged, clean the pipe & strainer.
If the delivery head is higher than specified, select the suitable pump set.
If the suction pipe has leakage, make it airtight.
If the pipe size diameter is smaller than recommended, use the correct diameter.
   